Uploaded image for project: 'Spring Integration'
  1. Spring Integration
  2. INT-4024

TCP: Failover of Caching Connection Factory Does not Work with OB Gateway

    XMLWordPrintable

    Details

      Description

      When FailOver is on top of Cached (connection factories) and single-use is true (required when using a CCCF), a new FailoverConnection is created. However, the delegate's listener (the failover connection) is not updated, so the "reply" has the wrong connection id.

      Work around is to configure the Caching factory to wrap the Failover factory.

        Attachments

          Activity

            People

            Assignee:
            grussell Gary Russell
            Reporter:
            grussell Gary Russell
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved: