      Description

      At a certain project size the "DataNucleus Enhancer" run config, which seems to be created and managed by roo after you do "gwt setup", fails to execute because the command line length is too large.

      In my project it's at 148775 with a windows maximum of 8191 (http://support.microsoft.com/kb/830473/en-us).
      At this length I get a "CreateProcess error=206" but I've also experienced error=87 like the poster in the forum reference.

      http://www.datanucleus.org/products/accessplatform/enhancer.html suggests different ways of handling byte code enhancements.